PourThru Reader.
PourThru Reader
Run a PourThru test, read the pH and EC against your crop's targets, and keep the readings so you can see the trend.
A PourThru test reads the nutrient solution in a pot without disturbing the roots. Water the crop as usual, let the pots drain for 30 to 60 minutes, set a saucer under each pot, and pour enough distilled water over the surface to collect about 50 mL (1.7 oz) of leachate, then measure its pH and EC. For a 4 to 6 inch pot that takes about 75 mL (2.5 oz) of water. Test five to ten pots of the same crop and go by the average (Purdue Extension). Enter your readings below for the average, how it compares with your crop's range, and a record you can chart week to week.
How to do a PourThru test
- Water as usual. Irrigate or fertigate the crop the way you always do; if you feed once a week, test on the same day each week (Purdue). For large containers, water to container capacity, with 10% to 20% running out of the drainage holes (e-GRO 10.10).
- Wait. Let the pots drain for 30 to 60 minutes (Purdue). Large containers can take 30 minutes to 2 hours to settle (e-GRO 10.10). Calibrate the meter while you wait.
- Set a saucer under each pot.
- Pour distilled water evenly over the substrate surface, circling the plant rather than pouring in one spot (e-GRO 10.10), to collect about 50 mL (1.7 oz) of leachate. The amount to pour depends on the pot: see the table below.
- Measure the pH and EC of each sample separately, and soon: leachate pH can change within 2 hours (e-GRO 10.10).
- Average the five to ten pots of each crop, and decide on the average (Purdue).
Distilled water to pour, by container
Two extension sources give starting amounts, and for nursery containers they differ, so start with the smaller figure and add a little more if less than 50 mL comes out. Purdue warns that more than 70 mL of leachate dilutes the sample; for large containers, e-GRO accepts up to 90 mL (3 oz).
| Container | Purdue, after NC State | e-GRO Alert 10.10 |
|---|---|---|
| Flat (606, 1203 or 1204) | 50 mL (2.0 oz) | not listed |
| 4, 5 or 6 inch pot | 75 mL (2.5 oz) | not listed |
| 6.5 inch azalea pot | 100 mL (3.5 oz) | not listed |
| 1 quart | 75 mL (2.5 oz) | 70 mL (2.4 oz) |
| 1 gallon | 150 mL (5.0 oz) | 75 mL (2.5 oz) |
| 3 gallon | 350 mL (12.0 oz) | 80 mL (2.9 oz) |
| 5 gallon | not listed | 120 mL (4.1 oz) |
| 10 gallon | not listed | 150 mL (5.1 oz), for 90 mL of leachate |
Reading the results
The reader checks your average against the crop's PourThru EC range and pH group right here, from Purdue Extension's tables (adapted from NC State). The same targets for every test method are in the Crop pH and EC Lookup. It also places the EC on Purdue's PourThru scale: below 1.0 mS/cm very low, 1.0 to 2.6 low, 2.7 to 4.6 normal, 4.7 to 6.5 high, 6.6 to 7.8 very high and over 7.8 extreme.
When the pots disagree. PourThru results vary more than other methods. A pot that was dry reads a higher EC because the salts are more concentrated, and too much water dilutes the sample and reads low. Watering as usual and measuring the water you pour keeps the variation down (Purdue).
The trend matters most. One test is a snapshot. Plotting pH and EC every week shows drift before it shows on the leaves, and gives a lab or extension agent the history they need if a problem comes up (Purdue). The reader keeps your tests and draws that chart.
For perennials, nursery stock and hemp grown in large containers, e-GRO Alert 10.10 lists its own PourThru pH and EC ranges by crop.
What it does not do
- It does not replace a lab test. A lab's substrate analysis gives the individual nutrients; PourThru gives pH and total salts.
- Records are kept in this browser only. Clearing the browser's data deletes them, so download a copy you want to keep.
- Crops not in the lookup get the 5.8 to 6.4 pH range for most crops and Purdue's general EC scale, not a crop-specific range.
- It does not check the meter. A reading is only as good as the last calibration (e-GRO 10.10).
Learn more from the extension specialists
- e-GRO Alert 10.10, PourThru Method for Large Containerized Crops (Owen, Kentucky, 2021): the kit, the steps, water volumes and crop ranges for perennials and nursery stock.
- e-GRO Alert 6.37, Monitoring pH and EC of Growing Medium (Cabrera and Raudales, UConn, 2017): PourThru beside the SME, 1:2 and squeeze methods.
- e-GRO Alert 7.02, Corrective Procedures for Modifying Substrate pH and Electrical Conductivity (EC) (Whipker, Henry and Owen, 2018): what to do when a reading is off.
- e-GRO Alert 14.52, Meter Matters: Selecting a pH and EC Meter (Veazie, Finn and Whipker, NC State, 2025).
- Every e-GRO alert on substrate pH and EC in Greenhouse Alerts.
Sources
- Camberato, D.M., R.G. Lopez and M.V. Mickelbart. pH and Electrical Conductivity Measurements in Soilless Substrates. Purdue Extension HO-237-W. The PourThru steps, the 50 and 70 mL leachate figures, Table 3 (water by container) and Table 2 (EC bands), adapted from Cavins et al., NC State HIL-590 (2000); sampling five to ten pots; variability; tracking over time.
- Owen, W.G. 2021. PourThru Method for Large Containerized Crops. e-GRO Alert 10.10. Leaching 10% to 20%, the 30-minute to 2-hour wait, pouring around the plant, Table 1 (water by container, 50 to 90 mL of leachate), calibration standards, testing within 2 hours.
- Cabrera, J. and R. Raudales. 2017. Monitoring pH and EC of Growing Medium. e-GRO Alert 6.37. When to use PourThru and when not.
- Lopez, R.G., M.V. Mickelbart and C. Pasian. 2010. Alkalinity Management in Soilless Substrates. Purdue Extension HO-242-W. Crop pH groups.
CC BY 4.0. Cite as "Open Agriculture Technology PourThru Reader (openagriculturetechnology.com)".
Frequently asked questions.
How do you do a PourThru test?
Water the crop as usual, let it drain for 30 to 60 minutes, set a saucer under each pot, and pour enough distilled water over the substrate to collect about 50 mL (1.7 oz) of leachate. Measure the pH and EC of each sample, test five to ten pots of the crop, and go by the average (Purdue Extension).
How much water do I pour for a PourThru?
About 75 mL (2.5 oz) of distilled water for a 4 to 6 inch pot, 100 mL (3.5 oz) for a 6.5 inch azalea pot and 50 mL (2 oz) for a flat (Purdue). For nursery containers the sources differ: 75 to 150 mL for a 1 gallon and 80 to 350 mL for a 3 gallon. Start with the smaller amount and add more until about 50 mL comes out.
What is a good PourThru EC?
It depends on the crop. Light feeders such as impatiens, pansy and plugs: 1.0 to 2.6 mS/cm. Medium feeders such as petunia, geranium and hydrangea: 2.0 to 3.5. Heavy feeders, chrysanthemum and poinsettia: 2.6 to 4.6. Above 4.6, growth slows, especially in hot weather (Purdue, after NC State).
What pH should a PourThru read?
The same as the substrate target, since pH reads the same by every method: 5.8 to 6.4 for most crops, 5.4 to 6.2 for petunia, calibrachoa and the other iron-inefficient crops, and 6.0 to 6.6 for geranium, marigold and the other iron-efficient crops (Purdue Extension; e-GRO Alert 6.37).
How long after watering should I do a PourThru?
30 to 60 minutes after a normal irrigation or fertigation (Purdue), and up to 2 hours for large nursery containers (e-GRO Alert 10.10). Test the same way each time, ideally on the same day each week.
Can I use the PourThru method with slow-release fertilizer or subirrigation?
Slow-release fertilizer, yes: PourThru is the preferred method then, because prills in a scooped sample inflate the EC. Subirrigation, no: salts collect at the top of the pot and a PourThru can wash them into the sample, so use the saturated media extract, 1:2 or squeeze method (e-GRO Alert 6.37).
Why are my PourThru readings so different from pot to pot?
A dry pot reads a higher EC because the salts are more concentrated, and pouring too much water dilutes the sample and reads low. Water the crop as usual before testing, measure the water you pour, and average five to ten pots (Purdue Extension).
How do I calibrate a pH and EC meter for PourThru?
Calibrate pH with fresh 4.0 and 7.0 standards, and EC with the 1.413 mS/cm standard most meters call for; never pour used standard back into the bottle (e-GRO Alert 10.10). Calibrate at least weekly (e-GRO Alert 6.37).