A fruiting room's humidifier has to put back the water that fresh air carries away, so its size is set mostly by how much outside air comes in and how dry that air is once it warms to room temperature. We found no extension guide that gives a sizing rule; the Cornell and Fungi Ally farm book says only that ultrasonic humidifiers are enough for rooms up to 400 square feet. The method below uses standard weather formulas. By our arithmetic, a 10 by 10 by 7 foot room held at 62°F and 90% humidity, taking in winter air at 40°F and 80% at 6 air changes an hour, needs about 2 pounds of water an hour, a quarter of a gallon; on Cornell's timed fan schedule, about 3 pounds.
What the sources say
The growing guides describe the equipment and the targets, not the size. What they do say:
- Cornell Small Farms says humidity is usually held with a commercial humidifier and a humidistat or timer that switches it on and off.
- The Cornell and Fungi Ally farm book lists the options: home humidifiers, ultrasonic misters, carbonator pumps with atomizing nozzles, or wetting the floor and walls several times a day. It says ultrasonic humidifiers cost considerably less and are sufficient for rooms up to 400 square feet, and that larger rectangular rooms do well with pressurized misting systems.
- ATTRA's 2026 guide suggests light, frequent misting for small setups and humidifiers or foggers for rooms, always with air moving so surfaces do not stay wet, and a tray of damp perlite where the air feels dry.
- Agromisa, writing for simple mushroom houses, keeps humidity at 80 to 90% by spraying water several times a day.
- Mercy For Animals' Transfarmation Project, a non-profit, published a design for an 11 by 24 by 8 foot room with an ultrasonic humidifier rated at 6 pounds of water an hour. The design does not say what air exchange rate or outdoor conditions that figure was chosen for. It notes that humidity dissipates over time through imperfect seals and the drying effect of air conditioners.
None of these gives a way to work out the size for a different room. The rest of this page is our method, built on standard weather formulas, and compared with the one sized example above.
Why fresh air sets the size
R. H. Kurtzman's review of ventilation for mushroom growing sets out the physics. Cool air holds less water vapour than warm air, and what we notice is relative humidity, how full the air is for its temperature, rather than absolute humidity, how much water it actually carries. With fans, moist air leaves the room faster, but water vapour can be added to the incoming air; Kurtzman calls controlled temperature the most important factor in controlling the water vapour in the air.
Warming air changes its relative humidity but not the water it carries. So outside air that feels damp in winter is dry once it reaches the room: the fruiting page works the example of air at 40°F and 80% falling to about 35% at 62°F (our arithmetic). The humidifier has to supply the difference between what that air carries and what the room needs, for every cubic foot that comes in. The humidity and VPD page explains the drying power of air in more detail.
The method, step by step
All of this section is our arithmetic. The formulas are the US National Weather Service's for saturation vapour pressure and mixing ratio (the mass of water per mass of dry air); air density comes from the ideal gas law at sea-level pressure.
- Work out how much outside air comes in each hour. Either the room's volume times the air changes an hour, or the fan's rating in cubic feet per minute times the minutes it runs each hour. Cornell's example room is 10 by 10 by 7 feet, 700 cubic feet.
- Find how much water that air carries. From the outside temperature and relative humidity, the NWS formulas give the mixing ratio. Air at 40°F and 80% carries about 4.2 grams of water per kilogram of dry air. Warming it does not change this number.
- Find how much water the room air carries at your target. At 62°F and 90%, inside UC Cooperative Extension's 85 to 92% for cropping oyster, it is about 10.7 grams per kilogram.
- Multiply the difference by the mass of air. Air at 62°F and sea-level pressure weighs about 0.076 pounds per cubic foot. One change of Cornell's 700 cubic feet is about 53 pounds of air; at 6.5 grams more water per kilogram, the humidifier must add about 0.35 pounds of water to bring it up to target.
- Size for the hardest case you expect. Our suggestion: use the coldest, driest outside air the room will draw and the highest air change rate you plan to run. How much margin to add above that is a judgment; we found no source for it.
| Quantity | How we got it | Source |
|---|---|---|
| Saturation vapour pressure | 6.11 × 10(7.5T / (237.3 + T)) hectopascals, with T in °C | National Weather Service |
| Water carried by the air | Mixing ratio = 621.97 × e / (P − e) grams per kilogram, with e the actual vapour pressure and P the air pressure, taken as 1,013 hectopascals | National Weather Service |
| Weight of air | About 0.076 lb per cubic foot at 62°F at sea level; less at altitude | Our arithmetic, ideal gas law |
| Target | 62°F and 90% relative humidity | UC Cooperative Extension’s oyster cropping range, our choice within it |
Worked examples
Water a 700 cubic foot room needs added each hour to stay at 62°F and 90%, by outside air and air change rate: from about 0.9 pounds an hour on a mild 55°F day at 4 changes, to about 5.3 pounds on a 30°F day at 12 changes. All figures are our arithmetic by the method above. They treat all incoming air as outside air, because that is the air that has to be brought up to the room's humidity; a room that recirculates part of its own air through the fan needs less.
| Air changes an hour | 55°F, 70% outside | 40°F, 80% outside | 30°F, 70% outside |
|---|---|---|---|
| 4 (UC, low) | 0.9 (0.11) | 1.4 (0.17) | 1.8 (0.21) |
| 6 (UC, high) | 1.4 (0.16) | 2.1 (0.25) | 2.6 (0.32) |
| 12 (Cornell, high) | 2.7 (0.33) | 4.2 (0.50) | 5.3 (0.63) |
UC gives 4 to 6 air changes an hour for cropping oyster; Cornell changes all the air every 5 to 10 minutes, 6 to 12 an hour. At 30°F and 70%, outside air warmed to 62°F is at about 21% relative humidity; at 55°F and 70%, about 55% (our arithmetic). The colder the air, the more each change costs.
Cornell's fan schedule. Cornell's example runs a 720 cubic foot per minute fan for 60 seconds about every 7 minutes. That brings in about 6,200 cubic feet an hour, almost 9 room volumes. At 40°F and 80% outside it needs about 3 pounds of water an hour (0.37 gallons); at 30°F and 70%, nearly 4 pounds (our arithmetic). Our method counts the outside air that comes in, so a short strong burst and a slow fan cost the same water when they move the same volume.
Compared with the one sized example. For Mercy For Animals' 11 by 24 by 8 foot room, 2,112 cubic feet, a 6 pound an hour humidifier covers about 5.7 air changes an hour at 40°F and 80% outside, about 4.5 at 30°F and 70%, and about 8.8 at 55°F and 70%, by our arithmetic. Those rates sit inside the air change rates the sources give for oyster (UC: 4 to 6 an hour; Cornell: every 5 to 10 minutes, 6 to 12), so the method and the design are of the same size. That is a rough comparison only: it is one example, and the design does not state the conditions behind it.
What the method leaves out
The method counts only the water fresh air carries in and out. Several things move the real answer, and we found no source that measures them for a fruiting room:
- Water from the blocks and mushrooms. Mushrooms lose water from their surface as they grow: Agromisa explains that the moisture flow that feeds them only continues while water evaporates from the cap. Kurtzman notes that much less water vapour comes off substrate in plastic bags than off open beds. How much a block or a flush adds to the room's air is a gap in every source we have, so the method leaves it out. Water they give off is water the humidifier does not have to supply, so leaving it out makes the figures above high rather than low; by how much, no source says.
- Misting and wet floors. The farm book and Kurtzman both describe wetting floors and walls, and UC mists oyster once or twice a day. That water evaporates into the room and does some of the humidifier's work. The method leaves it out.
- Leaks. Kurtzman points out that most buildings leak air, and Mercy For Animals names imperfect seals. Air that leaks in is fresh air the fan count misses, so a leaky room needs more water than the table shows.
- Air conditioning. A cooling coil takes water out of the air, and Mercy For Animals names it as a cause of humidity loss. In summer, warm outside air can carry more water than the room needs, and the work shifts to the cooling: air at 85°F and 60% has a dew point near 70°F, so cooling it to 62°F wrings water out on the coil (our arithmetic, on the fruiting page).
- What a humidifier actually delivers. A rating is the maker's figure. We have no source on how much of it reaches the air in a cool, already humid room.
Because of these, the table is a starting point for choosing equipment, not a measurement. A humidity reading over a few fan cycles shows how far each air change pulls the room down and how long the humidifier takes to recover.
Choosing and running one
- Size and type. For small rooms, the farm book's guidance is ultrasonic humidifiers up to 400 square feet, and pressurized misting systems for larger rectangular rooms. Mercy For Animals' guide adds that ultrasonic units give a finer mist.
- Control. A humidistat or timer switches the humidifier (Cornell). A humidistat answers what the air is doing; a timer does not.
- Clean water, clean unit. Mercy For Animals stresses that the water must be free of contaminants and that equipment should be cleaned completely at least every two weeks.
- Where it sits. Mercy For Animals keeps the humidifier outside the fruiting room, in a buffer space it calls a plenum, where incoming air can be brought to temperature and humidity before it enters the room. That also keeps the equipment out of the room's spores and dirt.
- Not onto the mushrooms. The farm book warns that mushrooms soak up water like sponges and, kept wet, get diseases such as blotch.
→ Which humidity sensor to trust at 90%: sensors in a fruiting room.
→ The same method for your own room and weather: the fruiting room humidifier and fan calculator.
→ Room volume, fan size and air changes an hour: the air exchange calculator.
Related pages
Sources
- Cornell Small Farms Program. Methods of Commercial Mushroom Cultivation in the Northeastern United States: 2. Seven Stages of Cultivation. Humidifier with a humidistat or timer; the 700 cubic foot room and the timed 720 CFM fan; allowing for what fresh air does to humidity.
- Crosby, W. (Fungi Ally) and S. Gabriel (Cornell Small Farms Program). 2021. Specialty Mushroom Farm Book. Northeast SARE. Creating a fruiting room: the humidifier options, ultrasonic units up to 400 square feet, not wetting the mushrooms.
- Soto-Velez, G. 2026. Mushroom Cultivation (IP677). ATTRA, National Center for Appropriate Technology. Misting, humidifiers and foggers with airflow, damp perlite (p. 12).
- Oei, P., with B. van Nieuwenhuijzen. 2005. Small-scale mushroom cultivation (Agrodok 40). Agromisa Foundation and CTA. Evaporation from the cap (p. 12); spraying to hold 80 to 90% (p. 49).
- Kurtzman, R. H. Jr. 2010. Ventilation for mushroom cultivation: the importance of the needs of mushrooms and of the gas laws. Micología Aplicada International 22(2): 63–78. Relative and absolute humidity (p. 74); adding water vapour to incoming air and temperature control (p. 75); less vapour from bagged substrate (p. 76); buildings leak air (p. 77).
- University of California Cooperative Extension. 2011. Cultivating Mushrooms on Small Farms (slides). Oyster cropping humidity and air changes (p. 34); misting (p. 29).
- Transfarmation Project, Mercy For Animals. 2023. 11' x 24' x 8' Site Modification for Specialty Mushroom Cultivation. A non-profit's room design: the 6 pound an hour humidifier and why humidity dissipates (p. 9). And Critical Elements of a Mushroom Fruiting Room: the plenum, ultrasonic mist, clean water and cleaning (pp. 3 and 4).
- National Weather Service, El Paso office. Vapor Pressure and Mixing Ratio. The two formulas the method uses.
- Sensirion. SHT3x-DIS datasheet, version 7, December 2022. The SHT31's best-performance humidity range.
Frequently asked questions.
How big a humidifier do I need for a mushroom fruiting room?
It depends mostly on how much outside air you bring in and how dry it is. By our arithmetic from National Weather Service formulas, a 10 by 10 by 7 foot room held at 62 F and 90% needs about 1.4 to 2.6 pounds of water an hour at 4 to 6 air changes, with outside air between 40 F at 80% and 30 F at 70%. The Cornell and Fungi Ally farm book says ultrasonic humidifiers are enough for rooms up to 400 square feet. We found no extension guide with a sizing rule.
How much water does a mushroom grow room use for humidity?
For each change of air, the humidifier has to add the difference between the water the room needs and the water the outside air carries. By our arithmetic, one change of a 700 cubic foot room at 62 F and 90% takes about 0.35 pounds of water when outside air is 40 F and 80%. At 6 changes an hour that is about 2 pounds, a quarter of a gallon, an hour. Water from the blocks and from misting reduces it; leaks increase it.
Is an ultrasonic humidifier good for growing mushrooms?
For small rooms, yes. The Cornell and Fungi Ally farm book says ultrasonic humidifiers cost considerably less than pressurized misting systems and are sufficient for rooms up to 400 square feet. A guide from the Transfarmation Project of Mercy For Animals says ultrasonic units give a finer mist, and stresses clean water and cleaning the equipment at least every two weeks.
Why does the humidity drop every time my fan comes on?
Because the fan replaces the room's damp air with outside air, which is drier once it warms to room temperature. Air at 40 F and 80% falls to about 35% relative humidity at 62 F (our arithmetic). Cornell Small Farms tells growers to allow for what fresh air does to humidity, and ATTRA advises raising misting or humidification when mushrooms dry after airflow goes up.
Why can't my humidifier keep up in winter?
Cold air carries little water, so each air change in winter takes more water to bring up to fruiting humidity. By our arithmetic, a change of a 700 cubic foot room at 62 F and 90% takes about 0.23 pounds of water with outside air at 55 F and 70%, and about 0.44 pounds at 30 F and 70%. Size the humidifier for the coldest, driest air the room will draw at the highest air change rate you run.
Do I need a humidistat for a mushroom humidifier?
Cornell Small Farms says fruiting room humidity is usually held with a commercial humidifier switched by a humidistat or a timer. A humidistat responds to the air; a timer runs whatever the air is doing. Check the humidity sensor itself: Sensirion says its SHT31 performs best between 20 and 80% relative humidity, below a fruiting room's range.
Should the humidifier be inside the fruiting room?
Not necessarily. A guide from the Transfarmation Project of Mercy For Animals keeps the humidifier outside the fruiting room, in a buffer space where incoming air can be brought to temperature and humidity first, which also keeps the equipment away from spores. Wherever it sits, the Cornell and Fungi Ally farm book warns against wetting the mushrooms directly.
Does misting count toward room humidity?
Partly. Water misted onto floors, walls and blocks evaporates into the air and does some of a humidifier's work; Agromisa holds simple mushroom houses at 80 to 90% by spraying water several times a day. How much it adds is not measured in any source we found, so our sizing method leaves it out. Do not spray mushrooms that are nearly ready to pick (Agromisa).