Fruiting Room Humidifier and Fan.
Fruiting Room Humidifier and Fan Calculator
The fresh air a mushroom fruiting room takes in, and the water a humidifier has to add each hour to keep up.
A fruiting room's humidifier has to put back the water that fresh air carries away, so its size is set mostly by how much outside air comes in and how dry that air is once it warms to room temperature. By our arithmetic from National Weather Service formulas, a 10 by 10 by 7 foot room held at 62°F and 90%, taking in outside air at 40°F and 80% six times an hour, needs about 2.1 pounds of water an hour, a quarter of a gallon. We found no extension guide that gives a sizing rule, so the figures here are a starting point for choosing equipment, not a measurement.
How the calculation works
All of this is our arithmetic, the same method as the humidifier sizing page, so the page and the calculator give the same answers. Warming air changes its relative humidity but not the water it carries, so outside air that feels damp in winter is dry once it reaches the room. The humidifier supplies the difference between what that air carries and what the room needs, for every cubic foot that comes in.
- Air in each hour. The room's volume times the air changes an hour; or a fan's flow, running all the time; or a fan's flow times the share of each hour it runs.
- Water the outside air carries. Saturation vapour pressure is 6.11 × 10(7.5T / (237.3 + T)) hectopascals, with T in °C; the actual vapour pressure is that times the relative humidity. The mixing ratio, grams of water per kilogram of dry air, is 621.97 × e / (P − e), with P taken as 1,013 hectopascals (National Weather Service). Air at 40°F and 80% carries about 4.2 g/kg.
- Water the room air carries. The same formulas at the room's temperature and humidity: about 10.7 g/kg at 62°F and 90%.
- Weight of the air. From the ideal gas law at the room's temperature and sea-level pressure: about 0.076 lb per cubic foot at 62°F. One change of a 700 cubic foot room is about 53 lb of air.
- Water to add. The difference in mixing ratio times the weight of air coming in. A US gallon of water is taken as 8.34 lb.
The calculator treats all incoming air as outside air, because that is the air that has to be brought up to the room's humidity. A room that recirculates part of its own air through the fan needs less. A short strong burst and a slow fan cost the same water when they move the same volume.
Worked examples
Water a 700 cubic foot room needs added each hour to stay at 62°F and 90%, as on the sizing page. The calculator gives the same figures.
| Air changes an hour | 55°F, 70% outside | 40°F, 80% outside | 30°F, 70% outside |
|---|---|---|---|
| 4 (UC, low) | 0.9 lb (0.11 gal) | 1.4 lb (0.17 gal) | 1.8 lb (0.21 gal) |
| 6 (UC, high) | 1.4 lb (0.16 gal) | 2.1 lb (0.25 gal) | 2.6 lb (0.32 gal) |
| 12 (Cornell, high) | 2.7 lb (0.33 gal) | 4.2 lb (0.50 gal) | 5.3 lb (0.63 gal) |
Cornell's fan schedule runs a 720 CFM fan for 60 seconds about every 7 minutes. That is 720 cubic feet in each run, and 60 ÷ 7, about 8.6 runs an hour, so about 6,200 cubic feet an hour come into the same 700 cubic foot room: 8.8 room volumes, the figure the calculator shows. At 40°F and 80% outside that takes about 3.1 lb of water an hour (0.37 gal); at 30°F and 70%, about 3.9 lb (our arithmetic). The fresh air page rounds the same schedule to about 8.6 changes an hour, because it takes the fan to replace exactly one room's air in each run.
What it does not do
- It counts only the water fresh air carries in and out. Water the blocks and mushrooms give off is water the humidifier does not have to supply, so leaving it out makes the figures high rather than low; by how much, no source we found says. Kurtzman notes that much less water vapour comes off substrate in plastic bags than off open beds.
- It leaves out misting and wet floors, which the farm book, Kurtzman and UC all describe, and which do some of the humidifier's work.
- It does not count leaks. Kurtzman points out that most buildings leak air; air that leaks in is fresh air the fan count misses, so a leaky room needs more water than the calculator shows.
- It does not model an air conditioner. A cooling coil takes water out of the air, and in summer warm outside air can carry more water than the room needs, so the work shifts to the cooling.
- It works at sea-level pressure. Air weighs less at altitude, so a room high up needs somewhat less water for the same air changes.
- It cannot say what a humidifier actually delivers. A rating is the maker's figure, and we found no source on how much of it reaches the air in a cool, already humid room. How much margin to add above the result is a judgment; we found no source for it. A humidity reading over a few fan cycles shows how far each air change pulls the room down and how long the humidifier takes to recover.
Learn more on the site
- Sizing a humidifier: the method, the worked examples and what the sources say about equipment.
- CO2 and fresh air: air change rates by mushroom and source, and working out a fan.
- Fruiting: the humidity, fresh air, light and temperature a fruiting room holds.
Sources
- Cornell Small Farms Program. Methods of Commercial Mushroom Cultivation in the Northeastern United States: 2. Seven Stages of Cultivation. The 700 cubic foot room; the 720 CFM fan run for 60 seconds about every 7 minutes; all the air every 5 to 10 minutes; a humidifier with a humidistat or timer.
- Crosby, W. (Fungi Ally) and S. Gabriel (Cornell Small Farms Program). 2021. Specialty Mushroom Farm Book. Northeast SARE. Ultrasonic humidifiers sufficient for rooms up to 400 square feet; pressurized misting for larger rectangular rooms; wetting floors and walls.
- Kurtzman, R. H. Jr. 2010. Ventilation for mushroom cultivation: the importance of the needs of mushrooms and of the gas laws. Micología Aplicada International 22(2): 63 to 78. Relative and absolute humidity (p. 74); adding water vapour to incoming air (p. 75); less vapour from bagged substrate (p. 76); buildings leak air (p. 77).
- University of California Cooperative Extension. 2011. Cultivating Mushrooms on Small Farms (slides). Oyster cropping at 85 to 92% humidity and 4 to 6 air changes an hour (p. 34); misting (p. 29).
- National Weather Service, El Paso office. Vapor Pressure and Mixing Ratio. The two formulas the calculator uses.
- Air density from the ideal gas law for dry air (gas constant 287.05 J per kg per kelvin) at 1,013 hectopascals; our arithmetic.
CC BY 4.0. Cite as "Open Agriculture Technology Fruiting Room Humidifier and Fan Calculator (openagriculturetechnology.com)".
Frequently asked questions.
How big a humidifier do I need for a mushroom grow room?
It depends mostly on how much outside air you bring in and how dry it is once it warms to room temperature. By our arithmetic from National Weather Service formulas, a 10 by 10 by 7 foot room held at 62°F and 90% needs about 1.4 to 2.6 pounds of water an hour at 4 to 6 air changes, with outside air between 40°F at 80% and 30°F at 70%. We found no extension guide with a sizing rule.
How do I calculate how much water a humidifier has to add to a room?
Work out the water each kilogram of outside air carries and the water each kilogram of room air needs, from temperature and relative humidity, using the National Weather Service's mixing ratio formula. Multiply the difference by the weight of air coming in each hour. For a 700 cubic foot room at 62°F and 90%, with outside air at 40°F and 80%, each air change takes about 0.35 pounds of water (our arithmetic).
Why does the humidity in my grow room drop every time the fan comes on?
Outside air carries less water than the room air, and warming it to room temperature lowers its relative humidity further. Air at 40°F and 80% outside is at about 35% once it reaches 62°F, and air at 30°F and 70% at about 21% (our arithmetic). Each air change replaces humid room air with that dry air, and the humidifier has to bring it back up.
How many air changes per hour does a mushroom fruiting room need?
UC Cooperative Extension gives 4 to 6 an hour for cropping oyster and 2 to 4 for shiitake. Cornell Small Farms changes all the air every 5 to 10 minutes, 6 to 12 an hour, for most species. A CO2 reading in your own room settles which end you need.
How do I convert air changes per hour to CFM?
Multiply the room's volume in cubic feet by the air changes an hour, and divide by 60. A 10 by 10 by 7 foot room, 700 cubic feet, at 6 changes an hour needs 700 × 6 ÷ 60 = 70 CFM running all the time (our arithmetic). A fan's rating is measured with nothing in the way, so filters and ducts cut what it actually moves.
Does running the fan in short bursts use less humidifier water than running it all the time?
Not by this method. The water the humidifier has to add depends on how much outside air comes in, so a short strong burst and a slow fan cost the same water when they move the same volume. Cornell prefers exchanging all the air in a minute or two to running a low-level fan all the time; by this method, that choice does not change the water the humidifier adds.
Why does my humidifier struggle more in winter?
Cold air holds little water, so once it warms up in the room it is very dry. By our arithmetic, a 700 cubic foot room at 62°F and 90% needs about 0.9 pounds of water an hour at 4 air changes on a mild 55°F, 70% day, and about 1.8 pounds on a 30°F, 70% day. Size for the coldest, driest air the room will draw and the highest air change rate you plan to run.
Is an ultrasonic humidifier big enough for a mushroom fruiting room?
For small rooms, the Cornell and Fungi Ally farm book says yes: ultrasonic humidifiers cost considerably less than pressurized misting systems and are sufficient for rooms up to 400 square feet. It says larger rectangular rooms do well with pressurized misting. Check the unit's rating, in pounds or gallons of water an hour, against what this calculator gives for your coldest conditions.