Supplemental Lighting Planner.
Supplemental Lighting Planner
How many grow lights your greenhouse needs, sized for your darkest month where you are, and what they cost to run through the year.
To size supplemental lighting, take your crop's target daily light integral (DLI), subtract the sunlight that reaches the crop in your darkest month, and spread the gap over the hours the lights can run. Each mol/m²/day supplied over 18 hours takes about 15.4 µmol/m²/s of light at the crop, so a 12 mol gap takes 185. Multiply that light level by the growing area and divide by one fixture's output in µmol/s for the number of fixtures. Enter your ZIP code below and the planner brings in your monthly outdoor DLI from NASA satellite data, then works out the fixtures, the hours they run each month and the electricity.
How the calculation works
Outdoor light where you are. NASA's POWER project publishes the average sunlight reaching the ground for every month at every point on a one-degree grid (about 110 km north to south), from satellite measurements of clouds and sun, averaged over 2001 to 2025. The planner uses the photosynthetically active part (PAR, 400 to 700 nm) and converts it to moles of photons with 4.57 µmol per joule, the figure for sunlight from Thimijan and Heins. Your ZIP code picks the grid cell that holds its Census center point.
Light inside. Glazing, framing, gutters and hanging baskets take their share before light reaches the crop: Purdue Extension puts the loss at 40% to 70% of outdoor DLI, which leaves 30% to 60% reaching the crop. The planner starts at 45%, the middle of that range; change it to your own figure. Your own greenhouse may differ, so measure it if you can: a quantum sensor or DLI logger at crop height, next to one outside, gives you the real figure (Purdue).
The gap and the light level. The supplemental DLI the lights must add is the target minus what arrives inside in the month you size for. Spread over the hours the lights can run, it gives the light level to install: µmol/m²/s = DLI ÷ (hours × 0.0036). e-GRO's worked example is lettuce in a northern greenhouse that gets 3 mol/m²/day in January, with a target of 15, between lettuce's minimum and optimum: the lights must add 12 mol over 18 hours, which is 185 µmol/m²/s.
Fixtures. One fixture's output in µmol/s divided by the light level is the area it can light. e-GRO's example fixture puts out 1,092 µmol/s, enough for 5.46 m² at 200 µmol/m²/s, so a 277 m² (3,000 ft²) greenhouse needs 51. The planner rounds up to whole fixtures and reports the light level they actually install.
Hours and electricity, month by month. With the fixtures installed, each month's gap divided by the installed light level gives the hours a day they need to run, never more than the most you allow. Hours times fixtures times watts gives the kilowatt-hours, and your rate gives the cost. These are averages: a dark week needs more, a bright one less, and lights controlled by a light-sum controller follow the weather.
What it does not do
- It uses long-term monthly averages, not a forecast or a particular year. Weather swings around these numbers.
- A ZIP code's center can be far from town in large rural ZIP areas, much of Alaska among them. The planner shows the grid cell it used; if it looks wrong, type your latitude and longitude instead.
- It does not lay out fixtures or check how evenly they light the crop. That takes the maker's photometric data for your house.
- It counts only the light. Lights also add heat, which can lower winter heating costs and raise summer cooling ones.
- The crop targets are e-GRO's rough guidelines. Optimal DLI also depends on temperature and carbon dioxide, and lettuce at high light needs strong air movement to avoid tipburn.
Learn more from the extension specialists
- e-GRO Food Crops Alert 2.05, How Many Light Fixtures Do I Need? (Mattson, Cornell, 2017): the method, the crop targets and the cost arithmetic this planner follows.
- e-GRO Food Crops Alert 5.04, LED Supplemental Lighting (Lopez, Michigan State, 2020).
- e-GRO Food Crops Alert 8.14, Online Tool to Aid Greenhouse Lighting Fixture Selection (Mattson, Cornell, 2023).
- e-GRO Alert 5.21, How Much Do Hanging Baskets Influence the Light Quality and Quantity for Crops Grown Below? (Lopez and Craver, 2016).
- e-GRO Alert 2.26, New Web-Based Supplemental Light Calculator (DLICALC) (Lopez, Currey and Krug, 2013), to check this one against.
- Every e-GRO alert on light and DLI, indexed by crop and problem, in Greenhouse Alerts.
Sources
- Mattson, N. 2017. How Many Light Fixtures Do I Need? e-GRO Food Crops Alert 2.05. The fixture-count method, the 185 µmol/m²/s and 51-fixture worked examples, the crop DLI guidelines (Table 1) and the 18-hour and dark-period guidance.
- Torres, A.P. and R.G. Lopez. Measuring Daily Light Integral in a Greenhouse. Purdue Extension HO-238-W. Greenhouse DLI 40% to 70% below outdoor, and measuring it.
- NASA Langley Research Center, POWER project. Climatology API, all-sky surface PAR (ALLSKY_SFC_PAR_TOT), January 2001 to December 2025, one-degree grid.
- Thimijan, R.W. and R.D. Heins. 1983. Photometric, radiometric, and quantum light units of measure: a review of procedures for interconversion. HortScience 18:818–822. 4.57 µmol of PAR photons per joule of sunlight.
- US Census Bureau, 2024 Gazetteer Files, ZIP Code Tabulation Areas: the center point of each ZIP code.
CC BY 4.0. Cite as "Open Agriculture Technology Supplemental Lighting Planner (openagriculturetechnology.com)".
Frequently asked questions.
How many grow lights do I need for my greenhouse?
Work out the light level the lights must add, multiply it by the growing area in square meters, and divide by one fixture's output in µmol/s. In e-GRO's example, lettuce needing 12 extra mol/m²/day over 18 hours needs 185 µmol/m²/s, and fixtures putting out 1,092 µmol/s each light about 5.9 m² at that level, so a 3,000 ft² house needs about 48. The planner above does this for your location, crop and fixture.
How do I calculate supplemental light for a greenhouse?
Subtract the DLI your crop gets in the greenhouse from its target DLI. That gap is the supplemental DLI. Divide it by the hours the lights can run and by 0.0036 to get the light level in µmol/m²/s. For example, 12 mol/m²/day over 18 hours is 12 ÷ (18 × 0.0036) = 185 µmol/m²/s.
What is the DLI in my area in winter?
Outdoors in December it runs from under 1 mol/m²/day in interior Alaska to about 6 in Seattle, 8 in central New York, 14 in Nashville, 22 in Phoenix and 30 in Honolulu, by NASA's 2001 to 2025 averages. Inside a greenhouse it is 40% to 70% lower (Purdue). Type your ZIP code into the planner for your own monthly figures.
What DLI does lettuce need?
e-GRO's guideline for head lettuce is a minimum of 12 mol/m²/day and an optimum of 17. At high light, lettuce is prone to tipburn, so it needs vertical air flow fans, or a lower target.
What DLI do tomatoes need in a greenhouse?
e-GRO's guideline is a minimum of 20 mol/m²/day and an optimum above 30, the same as peppers; cucumbers need at least 15. Tomatoes also need 4 to 6 hours of darkness a day, so their lights cannot run around the clock the way lettuce lights can.
How much light gets through a greenhouse cover?
Less than most growers expect. Purdue Extension puts greenhouse DLI at 40% to 70% below outdoor, after glazing, framing, structures and hanging baskets, which can leave as little as 1 to 5 mol/m²/day in winter. Measure your own with a quantum sensor or DLI logger at crop height.
How much does supplemental lighting cost to run?
Fixtures × watts ÷ 1,000 × hours a year × your rate per kWh. e-GRO's example of 51 fixtures at 700 W, on 3,000 hours a year at 6.5 cents per kWh, costs about $6,960 a year, or $2.32 per square foot for a 3,000 ft² house. The planner works it out month by month from your location, since the lights run far less in summer.
How many hours a day should greenhouse supplemental lights be on?
Long enough to close the gap between the natural DLI and the target, up to what the crop tolerates: e-GRO notes lettuce can take up to 24 hours of light a day without harm, while tomatoes need a 4 to 6 hour dark period. Longer hours at a lower light level reach the same DLI with fewer fixtures.