Calculators · Light & photoperiod

PPFD from Distance.

What this is
Calculator
Domain
Light & photoperiod
Account
None needed
Use
In the browser, or embed

PPFD Calculator

The average light level a grow light gives over the area it covers, the daily light integral that adds up to, and how a small lamp's reading changes when you move it.

The average light level a fixture gives (PPFD, in µmol/m²/s) is its total output (PPF, in µmol/s) divided by the area it lights in square meters, as long as all of its light lands there. A 1,700 µmol/s fixture over a 5 × 5 ft area (2.32 m²) averages about 730 µmol/m²/s. Hanging it higher or lower changes how evenly that light spreads and how much spills past the edges, not how much the fixture makes. Enter your fixture below for the average, the DLI it gives at 12, 16 and 18 hours, and, for a small lamp, what a reading becomes at a new height.

Average light over an area

From the fixture's spec sheet.

Total light output, from the spec sheet
5 × 5 ft = 25
100% is the planning assumption; light on walls and aisles is lost
Average light level –µmol/m²/s over the area
DLI over 12 hours –mol/m²/day
DLI over 16 hours –mol/m²/day
DLI over 18 hours –mol/m²/day

Moving a small lamp

For a single bulb hung well above the plants. Start from a reading you took, or one from the maker's chart.

Lamp to the top of the plants
Reading at the new height –µmol/m²/s by the inverse-square law

The inverse-square law holds for a light source that is small next to its distance from the plants. LED panels, bars and lamps with reflectors are not: for those, use the maker's light chart at your height, or measure with a quantum sensor.

How the calculation works

The average. A fixture's PPF is the total light it makes, in micromoles per second. Spread over an area, that light gives an average PPFD equal to the PPF divided by the area in square meters. This is the arithmetic e-GRO's lighting alert uses: a fixture putting out 1,092 µmol/s lights 5.46 m² at 200 µmol/m²/s. It assumes all the light lands on that area, so it is the most the area can get from that fixture.

Light that misses. Light that falls on walls, aisles and the floor is still made and paid for, but the crop never sees it. Nelson and Bugbee call the share that lands on the plants canopy photon capture, and found that as the growing area under a fixture gets smaller, more of the light is wasted. Set the share below 100% if you know some of your light lands elsewhere.

Height. Moving a fixture up or down does not change how much light it makes. It changes how that light is spread: higher spreads it wider and more evenly, so more of it can miss a small area; lower concentrates it under the fixture. For a small lamp well away from the plants, the reading follows the inverse-square law: at twice the distance, a quarter of the light. For panels and bars hung close to the plants that rule does not hold, which is why makers publish charts of PPFD at several heights.

DLI. The daily light integral is the light level times the hours it is on, times 0.0036 to turn micromoles per second into moles per day: 100 µmol/m²/s for 16 hours is 5.76 mol/m²/day (e-GRO).

What it does not do

  • It gives the average, not the spread. Real fixtures are brightest under the center and dimmer toward the edges; only the maker's chart or a meter shows by how much.
  • It does not know your fixture's optics or your room. Light bounced back from walls, and light lost past them, both change what the canopy gets.
  • It does not size a lighting system. For how many fixtures a greenhouse needs from the sunlight where you are, use the Supplemental Lighting Planner.
  • The height section is only for small lamps far from the plants, where the inverse-square law applies.

Learn more from the extension specialists

Sources

CC BY 4.0. Cite as "Open Agriculture Technology PPFD Calculator (openagriculturetechnology.com)".

Frequently asked questions.

How far should grow lights be from plants?

There is no single distance: it depends on the fixture and on how much light the crop needs. Decide the light level you want at the top of the plants, then find the height that gives it, from the maker's chart of light at different heights or with a quantum sensor. For lettuce, a DLI of 12 to 17 mol/m²/day over 16 hours means about 210 to 300 µmol/m²/s at the canopy (e-GRO).

What is a good PPFD for lettuce?

e-GRO's guideline for head lettuce is a DLI of 12 mol/m²/day minimum and 17 optimum. Over 16 hours of light that is about 210 to 300 µmol/m²/s; over 18 hours, about 185 to 260.

What PPFD do tomatoes need?

e-GRO's guideline for greenhouse tomatoes is a DLI of at least 20 mol/m²/day and over 30 for best growth. Over 16 hours, 20 mol takes about 350 µmol/m²/s and 30 mol about 520. Tomatoes need 4 to 6 hours of darkness a day, so their lights cannot simply run longer.

How do I convert PPFD to DLI?

Multiply the PPFD (µmol/m²/s) by the hours the light is on and by 0.0036. A light giving 100 µmol/m²/s for 16 hours delivers 100 × 16 × 0.0036 = 5.76 mol/m²/day (e-GRO).

How do I work out the PPFD from a grow light's PPF?

Divide the PPF by the area it lights in square meters (1 square foot is 0.0929 m²). A 1,700 µmol/s fixture over 5 × 5 ft (2.32 m²) averages about 730 µmol/m²/s, if all its light lands on that area. Light lost past the edges lowers the real figure.

Does the inverse-square law apply to grow lights?

Only to a small light source well away from the plants, where twice the distance gives a quarter of the light (HyperPhysics). LED panels and bars are broad and hang close to the plants, and reflectors and lenses steer the light, so their readings do not follow it. Use the maker's chart of PPFD at different heights, or measure.

Why is my measured PPFD lower than the spec sheet?

The spec sheet's PPF is all the light the fixture makes. Some of it lands outside the area you measure, on walls, aisles and floor, and the center reads higher than the edges. Nelson and Bugbee call the share that lands on the plants canopy photon capture. Measure at several points across the canopy, not just under the middle.