Power · Solar

Small solar,
built for one job.

Reading time
~14 minutes
Read first
Electrical safety
The parts, named
How a system works

A 12 volt, 100 watt solar panel with a 20 amp PWM charge controller and a 100 amp-hour LiFePO4 battery is a small system sized for one job at a time, such as a pump in a field, a LoRa gateway on a fence post, or lights and phone charging through a long power outage. Whether it fits depends on the watt-hours a day the job needs. On a sunny day the panel puts about 240 watt-hours into the battery, and about 180 on a short winter day. An inverter is optional; it belongs on the battery, never on the controller, and only when the job needs wall-outlet power.

Start with the job.

On this site, appropriate technology means technology matched to the job: the need, the scale, the budget, and the skills on hand. A solar kit is a clear case of it. Every part has a size, and every size is the right one for some job and the wrong one for another. A 100 watt panel is generous for a sensor node, about right for a stock-tank pump, and nowhere near enough for a freezer. The kit is the same in each case; whether it is the right size depends on the job.

So the first step happens before any shopping: list what has to run, multiply each item's watts by its hours a day, and add them up. That total, in watt-hours a day, is the need. The second number is your worst month's sun, because a system fails in the shortest days of the year (December, north of the equator), not in June. Sizing a System works that arithmetic in full; this page puts it to work on one kit and three jobs, and explains each part well enough that you can tell which job a kit fits before you buy it.

The panel: what 100 watts delivers.

“12 volt” names the battery the panel is built to charge, not its output. A typical 100 watt panel of this class works near 18 volts and 5.5 amps and reaches about 22 volts with nothing connected (its open-circuit voltage, Voc), a little more on a cold morning. The extra voltage is what lets it push charge into a battery through heat and wiring losses.

With a PWM controller, count amps, not watts. A PWM controller connects the panel to the battery and the panel's voltage drops to the battery's, about 13 to 14 volts, while its current stays near 5.5 amps. What reaches the battery is closer to 75 watts than 100, and over four peak sun hours that comes to about 19 amp-hours. The day's harvest is the panel current times the day's peak sun hours, less about 15 percent for heat, dust and wire (our working figure, not a rating):

One 100 W panel through a PWM controller
Peak sun hoursInto the batteryAbout
4 (a good day)~19 Ah240 Wh
3 (a short winter day)~14 Ah180 Wh
2 (a poor winter day)~9 Ah120 Wh

Peak sun hours depend on where you are and the month. The solar curve visualizer shows how a day's light adds up; NREL's PVWatts gives the figure for your address.

More panels: series or parallel.

Panels join two ways, and the choice changes the voltage and current the controller sees. In series, the positive of one panel goes to the negative of the next, and the voltages add while the current stays the same. In parallel, positive goes to positive and negative to negative, and the currents add while the voltage stays the same.

Two 100 watt panels wired in series, positive of the first to negative of the second, giving about 36 volts at 5.5 amps; and two wired in parallel, positive to positive and negative to negative, giving about 18 volts at 11 amps Series: volts add Panel 1 18 V · 5.5 A Panel 2 18 V · 5.5 A − + − + + to − ~36 V · 5.5 A same current, double the voltage Parallel: amps add Panel 1 18 V · 5.5 A Panel 2 18 V · 5.5 A − + − + ~18 V · 11 A same voltage, double the current With a PWM controller and a 12 V battery, wire panels in parallel.
Two 100 W panels, two ways. Red is positive, black is negative.
Two 100 W panels, series against parallel
SeriesParallelPWM pick
Working output~36 V at 5.5 A~18 V at 11 A
Open-circuit, cold morning~44 to 50 V~22 to 25 V
Shade on one panelcuts the whole string's current (bypass diodes soften it)only that panel loses its share
Wirelower current, so thinner wire over distancemore current, so heavier wire
With a PWM controllerno gain: the extra voltage is thrown awaythe added current all reaches the battery
Where it earns its placeMPPT controllers, long runs, bigger arrayssmall 12 V systems, short runs

Two more reasons decide it for this kit. A PWM controller lists a maximum panel input voltage on its label, and on many small units it is in the range of 25 to 50 volts; two panels in series on a cold morning can pass it and damage the controller. And series wiring only pays when the controller can convert the extra voltage into current, which is what an MPPT controller does (PWM and MPPT, compared).

Parallel has its own rules. Panels in parallel should share the same working voltage, and panels in series the same working current; a mismatched panel pulls the others toward its own number. Two panels join with a pair of MC4 branch connectors. At three or more in parallel, each panel needs its own fuse, sized to the “maximum series fuse” on its label, because the others can feed a fault in one of them. And with a PWM controller, keep the panels close: 11 amps at low voltage loses noticeably over a long run, and the wire and fuse calculator shows how much.

The charge controller.

The controller is the only part that deals with both the panel and the battery, and it does four jobs. It charges in stages: bulk (everything the panel gives), absorption (holding the battery near full voltage while the current tapers), and, for lead-acid, float (a lower holding voltage). It stops current flowing back into the panel at night. It offers load terminals for small DC equipment, with a low-voltage disconnect that switches the loads off before they drain the battery too far. And it shows you what is happening, by lights or a small screen.

20 amps against 40 amps. A 20 amp and a 40 amp controller of the same family do the same job; the larger one has more capacity. The rating is the most charging current it will pass to the battery. Builders size it with a margin of 1.25 on the panels' short-circuit current (Isc, about 6 amps for a 100 watt panel):

How many 100 W panels a PWM controller carries
ControllerPanels in parallelCharging current
20 A2~11 A
40 A5~28 A

6 A × 1.25 = 7.5 A per panel: two fit under 20 A, five under 40 A.

The right controller is the one sized to the job you have, with room for the next panel if the job may grow. One 100 watt panel uses about a quarter of a 20 amp controller, which leaves that room.

Three settings and limits matter on every small controller. The battery type setting (LiFePO4, AGM, flooded) chooses the charging voltages, so it must match the battery you connect; a controller without a lithium setting is the wrong one for a LiFePO4 battery. The system voltage (12 or 24) is usually detected from the battery when it is first connected, which is why the battery goes on first. And the load terminals carry a rating of their own, often 10 to 20 amps: right for a pump, LED lights or a USB adapter. The inverter section below explains why an inverter does not belong there.

The battery: LiFePO4.

A 12 volt, 100 amp-hour LiFePO4 battery stores about 1,280 watt-hours (12.8 volts × 100 amp-hours). Using 80 percent of it is routine for this chemistry, so plan on about 1,000. Its voltage stays nearly flat until it is almost empty, which equipment likes, and it carries a battery management system (BMS) inside that disconnects it when something goes wrong.

Two limits come from that BMS and belong on your list before you buy. It has a continuous current rating, commonly about 100 amps on a 100 amp-hour pack, which caps the inverter you can run from it. And most packs must not be charged below freezing; for a battery that lives outdoors through winter, look for low-temperature charge protection. The BMS is the last line of defence, not the plan. Batteries and Storage covers the chemistry, the cold, and lead-acid in depth.

Two batteries: parallel or series.

Batteries join the same two ways panels do, and the energy stored is the same either way. What changes is the voltage the rest of the system has to match.

Two 12 volt 100 amp-hour batteries in series make 24 volts at 100 amp-hours; two in parallel make 12 volts at 200 amp-hours, wired diagonally with the positive lead taken from the first battery and the negative lead from the second Series: 24 V Battery 1 12 V · 100 Ah Battery 2 12 V · 100 Ah − + − + 24 V · 100 Ah 2,560 Wh · a 12 V panel cannot charge it Parallel: 12 V, wired diagonally Battery 1 12 V · 100 Ah Battery 2 12 V · 100 Ah − + − + + out − out 12 V · 200 Ah 2,560 Wh · + from one battery, − from the other
Same two batteries, same energy. Series changes the voltage; parallel changes the capacity.

Parallel keeps 12 volts and adds the amp-hours: two 100 amp-hour batteries become one 200 amp-hour bank that runs the same loads twice as long. It is the way to grow this kit, because nothing else in it has to change. Take the system's positive lead from one battery and the negative from the other (the diagonal), with jumper cables of equal length and size, so both batteries carry an equal share instead of the nearer one working harder.

Series makes 24 volts at the same 100 amp-hours. Here is the catch that decides it for this kit: a 24 volt battery charges at around 28 volts, and a “12 volt” panel working at 18 cannot push current into it. A 24 volt bank needs panels in series and a controller set for 24 volts. It also needs 24 volt loads. Larger systems move to 24 volts to halve the current (roughly past 1,000 to 1,500 watts of inverter), which is a different kit.

Either way: same chemistry, same capacity, same age, and each battery charged full on its own before they are joined. LiFePO4 makers state how many of their packs may go in series or in parallel; stay within it.

Car batteries in an emergency.

When the power is out and the solar battery is somewhere else, the battery in a car or truck will work. It is not a deep-cycle battery, and that difference shapes how you use it.

A car battery is a starting battery: many thin lead plates, built to deliver several hundred amps for the few seconds it takes to crank an engine, then be topped up at once by the alternator. A deep-cycle battery has fewer, thicker plates, built to be drained slowly and recharged hundreds of times. Drain a starting battery deeply and its thin plates shed material; each deep cycle costs it noticeable life. In an emergency that trade is acceptable. As a permanent plan it is not.

Most car batteries are rated in cold-cranking amps and reserve minutes rather than amp-hours; a typical one holds roughly 45 to 60 amp-hours. Use about half: rested, a lead-acid battery reads about 12.7 volts full and about 12.2 at half. If the controller's low-voltage disconnect is adjustable, raise it toward 12 volts.

Two car batteries in parallel keep 12 volts and double the capacity and the current available: about 100 amp-hours, roughly 600 usable watt-hours. That is about three days of the outage kit below with no sun at all, and the 100 watt panel refills most of a day's use when the sun is out. Before you join them:

  • Bring them to the same voltage. Charge each one on its own first. Joining a battery at 12.7 volts to one at 11.8 sends a surge of current from one to the other, with sparks at the last clamp.
  • Check each one alone. A battery that falls below about 12.4 volts overnight after a full charge probably has a weak or shorted cell, and in parallel it will drain the good one. Leave it out.
  • Match them as closely as you can: same type, similar size and age. Wire diagonally with equal, heavy cables, and fuse the bank's positive lead.
  • Change the controller's battery type from LiFePO4 to the lead-acid type that matches: flooded for batteries with removable caps, AGM for the sealed kind many newer cars carry. The charging voltages differ, and the wrong setting undercharges one chemistry or overcharges the other.
  • Never put lead-acid and lithium in the same bank. Their voltages differ, and one will charge or drain the other.

Hook it up, in order.

Wiring of the small kit: the panel to the controller's PV terminals; the controller's battery terminals to the battery through a fuse at the battery; DC loads on the controller's load terminals; the optional inverter wired straight to the battery through its own fuse The small kit, wired 100 W panel ~18 V · 5.5 A Charge controller PWM · 20 A PV LOAD BATTERY DC loads pump · LEDs · USB LiFePO4 battery 12 V · 100 Ah fuse Inverter optional · DC → AC fuse Fuse every wire at the battery. The inverter goes to the battery, never to LOAD.
Panel to controller, controller to battery, small DC loads on the controller, the inverter on the battery.

The order matters because the controller learns the system from the battery, and because a panel in daylight is always live. Work with the battery fuse out until the end of each stage.

  1. Place the parts. Mount the controller close to the battery, where it stays dry and its heat can escape. A short, heavy cable between them lets the controller read the battery's voltage truly.
  2. Fit the battery fuse holder on the battery's positive terminal, with the fuse out.
  3. Wire the controller's BATTERY terminals to the battery: positive through the fuse holder, negative direct.
  4. Insert the fuse. The controller wakes, reads about 13 volts and sets itself for 12. Set the battery type now.
  5. Connect the panel last. Cover it or wait for dusk, then connect its leads to the PV terminals. Uncover it and check the controller shows charging.
  6. Add DC loads to the LOAD terminals with the load output switched off, then switch it on.
  7. If there is an inverter, give it its own cable pair and fuse, straight to the battery, with the inverter switched off. A small spark as the cable first touches is the inverter's capacitors filling, one more reason the fuse goes in last.

Taking it apart is the same list backwards: loads and inverter off, panel covered and disconnected, battery fuse out, then the battery cables.

The order, the write-in values from your labels, and the common faults fit on a printable card to keep with the controller.

The inverter, when you need one.

An inverter turns the battery's 12 volts DC into 120 volts AC, the power a wall outlet gives. It is the one optional part of this kit, and whether it belongs depends entirely on the job.

Why add one. Some equipment only comes in AC: a box fan, a power-tool battery charger, a laptop with an older power brick, a television, a small appliance. And sometimes the equipment you already own is the right equipment. In a power outage, a small inverter that runs what is already in the house can be a better fit than buying DC versions of everything for a few days of need.

When to leave it out. When the load already comes in DC. The stock-tank pump, the LoRa gateway, LED lights and USB charging all run from the battery or the load terminals directly, and a 12 volt USB-C charger of the kind made for cars charges a laptop that charges by USB-C without AC at all. There, an inverter adds conversion loss and a standing draw and does nothing the kit could not already do.

How to size it.

  1. Add up the running watts of everything that will run at the same time.
  2. Find the largest starting surge. Motors and compressors briefly draw three to five times their running watts when they start.
  3. Choose a continuous rating about 25 percent above the running total and a surge rating above the starting surge. Choose pure sine wave for anything with a motor or electronics.
  4. Work out the battery current: watts ÷ 12 ÷ 0.9 (the inverter's efficiency). Check it against the battery's BMS rating, then size the cable and fuse with the wire and fuse calculator. The cable must be rated above the fuse.
Inverter size against battery current, at 12 V
InverterBattery current at full outputFuse, aboutFits
150 W, plugs into a 12 V socket~14 Athe socket's own fusephone and laptop chargers
300 W pure sine~28 A40 Aa box fan, a router, a TV, chargers
1,000 W pure sine~93 A125 Aa small freezer's start, a tool charger

Fuse about 1.25 times the full-output current, rounded up to a standard size. Many 12 V accessory sockets are fused at about 15 A, which is why plug-in inverters stop near 150 W. A 1,000 W inverter is at the limit of a typical 100 Ah pack's BMS; many LiFePO4 makers specify a Class T fuse at the battery for currents this large.

Its cost while idle. An inverter draws power whenever it is on, loaded or not. The spec sheet lists it as no-load current. A unit that idles at half an amp uses 6 watts, about 144 watt-hours a day: most of what one panel makes on a winter day, before anything is plugged in. Switch it on when it has work and off when it is done.

Where it connects. To the battery, through its own fuse, never to the controller's load terminals. Those terminals are rated for small loads, often 10 to 20 amps, and even a 300 watt inverter's full output, let alone a motor's starting surge, is beyond them.

Three jobs, sized.

The need, and the solar that fits it
JobNeed a daySolar that fitsInverter
Stock-tank pump, 12 V~50 Whthe 100 W kit, or a panel-direct pumpno
LoRa field node~0.5 Wha 5 to 10 W panel and a small cellno
LoRa gateway, ESP32~10 to 25 Wh20 to 30 W, or the 100 W kit with room to spareno
Outage: lights and charging~190 Whthe 100 W kit and 100 Ahoptional, small
Small chest freezer~700 to 1,000 Whabout five panels, a 40 A controlleryes, ~1,000 W

Typical figures; measure your own equipment where you can. The freezer figure includes the inverter's standing draw.

A pump in the field.

A 12 volt diaphragm or submersible pump drawing about 4 amps for an hour a day uses about 50 watt-hours, well inside the kit even on a poor winter day. It runs from the controller's load terminals, so the low-voltage disconnect protects the battery. There is a simpler way still: a panel-direct pump runs only while the sun shines, with no battery at all, and the tank becomes the store. Storing water instead of electricity is often the better fit for watering livestock or filling a tank. The solar pump sizing tool works the numbers for a given lift and flow.

A LoRa node or gateway.

A LoRa field node averages a few milliamps, about half a watt-hour a day. A 100 watt kit is far more than it needs: a 5 to 10 watt panel and a small lithium cell carry it through winter (Solar for sensing works that case). A LoRa gateway on an ESP32 with its Wi-Fi on all day draws roughly half a watt to a watt, 10 to 25 watt-hours a day; it runs from a 12 volt-to-USB adapter on the load terminals and fits the kit with room to spare. Add a single-board computer and a router and the need climbs to 120 to 240 watt-hours; the 100 watt kit becomes the right size, and in a dark winter a little short.

When the power is out.

A long outage needs light, communication and a little comfort. Two phones at about 20 watt-hours each, one laptop at about 70, and four 12 volt LED lamps of 4 watts for five hours (80 watt-hours) come to about 190 watt-hours a day, close to what the panel makes on a short winter day. The 100 amp-hour battery alone carries that for about five days without sun. Warm-coloured LED lamps on 12 volts are worth having for their own sake: steady light in the evening eases the fear of a dark house, for children especially. Charge phones from USB sockets on 12 volts and the laptop from a 12 volt USB-C charger, and the inverter can stay off until something genuinely needs AC. Keep the panel outdoors and bring the cable in through a window or door.

The shortest version

Add up the job's watt-hours a day and size for your worst month. One 100 W panel through a PWM controller puts about 14 to 19 amp-hours a day into a battery. Wire extra panels in parallel; a 20 A controller carries two, a 40 A one about five. Grow batteries in parallel too, because a 24 V bank needs 24 V panels. Car batteries work in an emergency at half their capacity, matched, charged where hydrogen can vent, with the controller set to lead-acid. The inverter is optional: on the battery with its own fuse, sized for the starting surge, and switched off when idle.

Words to work from

The terms on the labels, manuals and spec sheets for a kit like this one.

Peak sun hour
An hour of full-strength sunlight. A day's light expressed as that many full hours; the number a harvest is worked from.
Short-circuit current (Isc)
The most current a panel can produce. Controllers, fuses and wire are sized from it, with a 1.25 margin.
Load terminals
The controller's output for small DC equipment, with a current rating of its own.
Low-voltage disconnect
The controller switching its load terminals off before the battery drains too far.
Battery type setting
The controller setting that chooses charging voltages for LiFePO4, AGM or flooded lead-acid.
Starting battery
A car battery: thin plates for a short, large burst of current. Deep drains shorten its life.
Deep-cycle battery
Built to be drained slowly and recharged many times. LiFePO4 and deep-cycle lead-acid are both of this kind.
Diagonal wiring
In a parallel bank, taking positive from one battery and negative from the other so both share the load.
No-load current
What an inverter draws when it is on with nothing plugged in.
Surge rating
The brief overload an inverter can carry while a motor or compressor starts.
Backfeed
Power flowing backward from an inverter into a building's wiring and the grid. A hazard to anyone working on the lines.

Put it to work

Size your own job before you buy a part: the watt-hours first, then the battery, then the wire.

Frequently asked questions.

What can a 100 watt solar panel run?

One modest job, done well. With a PWM controller a 12 volt, 100 watt panel puts roughly 19 amp-hours (about 240 watt-hours) into a battery on a day with four peak sun hours, and about 14 amp-hours (about 180 watt-hours) on a three-hour winter day. That covers a 12 volt stock-tank pump, a LoRa gateway with room to spare, or lights and phone and laptop charging through a power outage. It does not keep up with a freezer, which wants four to five times as much.

Should I wire solar panels in series or parallel?

With a PWM controller and a 12 volt battery, wire them in parallel. Parallel keeps the voltage near 18 and adds the currents, which is what a PWM controller can use. Series adds the voltages, which a PWM controller throws away and which can exceed its input limit on a cold morning. Series earns its place with an MPPT controller and long wire runs, where higher voltage means less current and thinner wire.

Can I use a car battery for solar?

In an emergency, yes. A car battery is a starting battery, built to deliver a large burst for a few seconds, and deep drains shorten its life quickly. Use about half its capacity, set the charge controller to the lead-acid type that matches it (flooded or AGM), charge it where hydrogen can vent, and never put it in the same bank as a lithium battery. Two matched car batteries in parallel give roughly 600 usable watt-hours.

Why connect the inverter to the battery and not the charge controller?

Because the controller's load terminals are rated for small loads, often 10 to 20 amps, and an inverter can draw far more. A 300 watt inverter at full output pulls about 28 amps from a 12 volt battery, a 1,000 watt one about 93, and motors briefly pull several times their running power when they start. Wire the inverter straight to the battery with heavy cable and its own fuse at the battery.

What size charge controller do I need for a 100 watt panel?

A 100 watt, 12 volt panel produces about 6 amps at most, so a 10 amp controller would carry it. A 20 amp controller does the same job with room for a second panel in parallel. Size by the panel's short-circuit current times 1.25 times the number of panels: two 100 watt panels on a 20 amp controller, about five on a 40 amp one.

How long will a 100 Ah LiFePO4 battery last in a power outage?

A 12 volt, 100 amp-hour LiFePO4 battery stores about 1,280 watt-hours, roughly 1,000 of them usable. A small outage kit of four LED lights for five hours, two phones and a laptop uses about 190 watt-hours a day, so the battery alone carries it about five days, and a 100 watt panel refills most of a day's use in winter sun.